SECTION 7 - TROUBLESHOOTING

1001070451

LIFTPOD by JLG

1-877-254-3876

7-2

www.liftpod.com

1-877-2-LIFTPOD

Powerpack (optional) motor does not start

Emergency stop button is engaged (PUSHED
IN) on powerpack

Disengage emergency stop button until it pops up (TURN CLOCKWISE).

Direction selector or enable trigger or speed
control trigger not activated

Select 'UP' on direction selector, then activate both the enable trigger and speed
control continuously for operation.

Battery not installed or no charge

Properly install charged battery in powerpack.

Motor has overheated

Wait until motor cools. The temperature cutout resets itself automatically.
Alternatively use manual descent procedure to lower platform (Section 4.1).

Platform does not lift up from bottom of travel - motor starts

Driveshaft interlock is engaged

Push cordless drill on driveshaft down firmly to disengage driveshaft safety inter-
lock.

(If using powerpack) Powerpack driveshaft not
engaged

Check powerpack is correctly fitted to platform, latch is down and drive shaft is
connected to carriage drive shaft.

Emergency brake not released from carriage
lock down latch position

Ensure a load greater than 50kg (110 lbs.) is in the platform (1 person) and lifting
ropes are tight. If latch has not released, attempt to lower the loaded platform
slightly then try again to lift up.

TROUBLE

PROBABLE CAUSE

REMEDY