SECTION 3 - TROUBLESHOOTING

3-14

– JLG Lift –

3120765

Brake Drags or runs hot.

Low actuation pressure.

Place pressure gauge in bleed port & check pres-
sure with system on.

Bearing failure.

Replace bearing.

Brake will not release.

Stuck or clogged valve.

Place pressure gauge in bleed port - check for
adequate pressure. Replace defective line or
component.

Bad o-rings.

Replace o-rings.

Discs frozen.

Replace disc stack.

Table 3-4.Chassis Assembly - Troubleshooting

TROUBLE

PROBABLE CAUSE

REMEDY