SECTION 3 - TROUBLESHOOTING
3-14
– JLG Lift –
3120765
Brake Drags or runs hot.
Low actuation pressure.
Place pressure gauge in bleed port & check pres-
sure with system on.
Bearing failure.
Replace bearing.
Brake will not release.
Stuck or clogged valve.
Place pressure gauge in bleed port - check for
adequate pressure. Replace defective line or
component.
Bad o-rings.
Replace o-rings.
Discs frozen.
Replace disc stack.
Table 3-4.Chassis Assembly - Troubleshooting
TROUBLE
PROBABLE CAUSE
REMEDY