SECTION 2 - PROCEDURES

2-54

– JLG Lift –

3120765

3= Motion Alarm - Sounds when any function is
active (Option)

7.

PLATFORM ALARM

0= Sounds continuously when above elevation
and tilted only.
1= Sounds continuously when above elevation and
tilted, and in conjunction with fault code flashes
(Option)

8.

BATTERY MONITOR

0=No Battery Monitor
1-20= Number of Charge/Discharge Cycles

Level Vehicle Description

A NEW TILT MODULE WILL ACT AS IF IT IS TILTED ALL OF THE
TIME UNTIL THE FOLLOWING PROCEDURE IS PERFORMED.

DO NOT LEVEL VEHICLE EXCEPT ON A LEVEL SURFACE.

LEVEL VEHICLE
YES:ENTER, NO:ESC

Not available at password level 2 ENTER confirms that
vehicle is currently level, and zeroes the tilt sensor mea-
surements

Help Descriptions and Fault Flash Codes

Table 2-7. JLG Control System Flash Codes

Code

Description

2-1

2-2

2-3

2-5

3-1

3-2

3-3

3-5

4-2

4-4

5-5

6-6

7-7

9-9

Faulty Footswitch/EMS

Drive/Steer inputs/Footswitch Interlocks

Boom function inputs/Lift-Swing Joystick

Function Cutout/Drive Cutout

Contactors miswired/Motors miswired

Line contactor welded

Contactor short circuit or valve short circuit

Brake pressure input

Controller Overtemperature

Battery voltage out of range

Speed Sensor input

CANbus inputs

Traction /Pump motor wiring or motor faulty

Power Module Failure

Updated 10-7-99