JLG E45A_AJ ANSI Service Manual User Manual

Page 85

Advertising
background image

SECTION 2 - PROCEDURES

3120765

– JLG Lift –

2-69

TEST ALL INPUTS?

Prompts whether to check every operator input. If ESC is pressed, the system test ends.
If ENTER is pressed, each operator input is prompted for in turn.
In platform mode, operator inputs are tested in the order: UL U, UL D, SWING L, SWING R, LEVEL U, LEVEL D,

PUMP POT, CREEP, ROTATE L, ROTATE R, LL U, LL D, JIB U, JIB D, TELE I, TELE O, DRIVE FWD,
DRIVE REV, STEER L, STEER R, POSITRAC

In ground mode, operator inputs are tested in the order: ROTATE L, ROTATE R. LEVEL U. LEVEL D, JIB U. JIB D,

TELE I, TELE O. UL U. IJL D, LL U. LL D, SWING L, SWING R

NOTE: the jib switches are not tested if JIB = NO.
Prompts displayed during the operator input test include:

CLOSE switchname

The named switch should be closed.

OPEN switchname

The named switch should be opened.

joystickname direction TO MAX

The named joystick should be pushed to its full extent in the named direction.

joystickname direction TO MIN

The named joystick should be returned to neutral from the named direction.

PUMP POT TO MAX

The pump pot should be turned to maximum.

PUMP POT TO MIN

The pump pot should be turned to minimum.

MULTIPLE CLOSURE

More than one operator input is closed; if only one has been operated, there could be a short between two inputs.

TESTS COMPLETE

Indicates that the system test is complete. Any problems reported should have been noted and should now be rectified.
Press ESC to return to the RUN SYSTEM TEST Analyzer menu.

Table 2-11. System Test Messages

Advertising
This manual is related to the following products: