SECTION 2 - PROCEDURES
2-52
– JLG Lift –
3120765
JIB
ACCELeration
0.5 to 5.0
1.5
DECELeration
0.5 to 3.0
0.5
MINimum UP speed
0 to 50
9
MAXimum UP speed
0 to 100
50
MINimum DOWN speed
0 to 25
6
MAXimum DOWN speed
0 to 100
35
MINimum RIGHT speed
0 to 50
5
MAXimum RIGHT speed
0 to 100
20
MINimum LEFT speed
0 to 50
5
MAXimum LEFT speed
0 to 100
20
STEER
MINimum speed
0 to 100
75
MAXimum speed
0 to 100
100
GROUND MODE
Lower LIFT UP speed
0 to 100
73
Lower LIFT DOWN speed
0 to 100
36
UPPER LIFT speed
0 to 100
51
SWING speed
0 to 100
19
TELEscope speed
0 to 100
53
BASKET ROTATE speed
0 to 100
21
BASKET LEVEL speed
0 to 100
30
JIB SWING speed
0 to 100
N/A
JIB LIFT speed
0 to 100
45
Table 2-5. Personality Ranges/Defaults