SECTION 2 - PROCEDURES

2-52

– JLG Lift –

3120765

JIB

ACCELeration

0.5 to 5.0

1.5

DECELeration

0.5 to 3.0

0.5

MINimum UP speed

0 to 50

9

MAXimum UP speed

0 to 100

50

MINimum DOWN speed

0 to 25

6

MAXimum DOWN speed

0 to 100

35

MINimum RIGHT speed

0 to 50

5

MAXimum RIGHT speed

0 to 100

20

MINimum LEFT speed

0 to 50

5

MAXimum LEFT speed

0 to 100

20

STEER

MINimum speed

0 to 100

75

MAXimum speed

0 to 100

100

GROUND MODE

Lower LIFT UP speed

0 to 100

73

Lower LIFT DOWN speed

0 to 100

36

UPPER LIFT speed

0 to 100

51

SWING speed

0 to 100

19

TELEscope speed

0 to 100

53

BASKET ROTATE speed

0 to 100

21

BASKET LEVEL speed

0 to 100

30

JIB SWING speed

0 to 100

N/A

JIB LIFT speed

0 to 100

45

Table 2-5. Personality Ranges/Defaults