PLUNGER VALVE TO ACTIVATE WHEN BOOM IS

RAISED BETWEEN 76° - 79°

NOTE: ADJUST SCREWS SO THAT PLUNGER ON VALVES HAS
0.25" (6.35 mm) TRAVEL REMAINING WHEN LOWER BOOM IS
FULLY RAISED AND RETRACTED

NOTE: ADJUST SCREWS SO THAT PLUNGER ON
VALVES HAS 0.25" (6.35 mm) TRAVEL REMAIN-
ING WHEN LOWER BOOM IS FULLY RAISED AND
RETRACTED

SWITCH TO ACTIVATE WHEN

UPRIGHT IS RAISED TO 40° - 42°

FROM STOWED POSITION. SWITCH

TO RESET WHEN UPRIGHT IS LOW-
ERED 25° TO 30° FROM ACTIVATED

POSITION.

SWITCH TO ACTIVATE WHEN BOOM IS 126 ± 1"

(320 ± 2.5 CM) FROM BEING FULLY EXTENDED

DUAL CAPACITY SWITCH TO ACTIVATE WHEN BOOM IS LOWERED TO 50°,

+5° -0°. SWITCH TO RESET WHEN BOOM IS RAISED TO 60°, +5° -0°.

SWITCH TO ACTIVATE WHEN BOOM

REACHES 0° TO 5° ABOVE HORIZONTAL.

SWITCH TO RESET WHEN BOOM IS

LOWERED 4°TO 9° BELOW HORIZONTAL.