2. Start the engine and bring to operating temperature.

3. With the engine running, close the manual tank

valve and run the engine out of fuel.

4. Push in the Emergency Switch once the engine

stops.

5. Disconnect the electrical connection to the LPG fuel

temperature sensor in the auxiliary fuel port of the
EPR.

6. Remove the retainer clip for the LPG fuel tempera-

ture sensor and remove the sensor from the regula-
tor body.

NOTE: Have a small container ready to collect oil that will

drain freely from the regulator at this point.

7. Once all of the oil has been drained, reinstall the

LPG fuel temperature sensor and reconnect the
electrical connector.

8. Open the fuel tank manual valve.

9. Start the engine and verify all connections are

secure.

10. Dispose of any drained oil in a safe and proper fash-

ion.

Propane Fuel Filter Replacement

REMOVAL

1. Relieve the propane fuel system pressure. Refer to

Propane Fuel System Pressure Relief.

2. Disconnect the negative battery cable.

3. Slowly loosen the Filter housing retaining bolt and

remove it.

4. Pull the filter housing from the Electric lock off

assembly .

5. Locate Filter magnet and remove it.

6. Remove the filter from the housing.

7. Remove and discard the housing seal.

8. Remove and discard the retaining bolt seal.

9. Remove and discard mounting plate to lock off O-

ring seal.

1. Electric Lock Off Solenoid
2. Mounting Plate
3. Housing Seal
4. Filter Magnet
5. Filter Housing
6. Seal

7. Electrical Connector
8. Fuel Outlet
9. O-ring
10. Filter
11. Fuel Inlet
12. Retaining Bolt

Figure 1-4. Filter Lock Assembly