Table 6-1. Personality Ranges/Defaults
FUNCTION
PERSONALITY
RANGE
DEFAULTS
DRIVE
ACCELeration
0.1s to 5.0s
2.0
DECELeration
0.1s to 3.0s
2.0
Forward MINimum speed
0 to 35%
4
Forward MAXimum speed
0 to 100%
35
REVerse MINimum speed
0 to 35%
4
REVerse MAXimum speed
0 to 100%
22
ELEVATED MAXimum speed
0 to 50%
10
CREEP MAXimum speed
0 to 50%
25
Engine RPM
800 to 2900
1800
TOWER LIFT
ACCELeration
0.1 to 5.0
1.0
DECELeration
0.1 to 3.0
0.5
MlNimum UP speed
0 to 60%
50
MAXimum UP speed
0 to 100%
100
MINimum DOWN speed
0 to 60%
50
MAXimum DOWN speed
0 to 100%
100
Engine RPM
800 to 2900
1800
UPPER LIFT
ACCELeration
0.1 to 5.0
2.0
DECELeration
0.1 to 3.0
0.7
MlNimum UP speed
0 to 60%
30
MAXimum UP speed
0 to 100%
55
CREEP Maximum UP speed
0 to 65%
55
MINimum DOWN speed
0 to 60%
40
MAXimum DOWN speed
0 to 100%
65
CREEP maximum DOWN speed
0 to 75%
55
Engine RPM
800 to 2900
1800