SECTION 6 - JLG CONTROL SYSTEM

3121201

– JLG Lift –

6-43

GEN SET/WELDER:
12

0

1

NO: No generator installed.

BELT DRIVE: Belt driven setup.

0

GEN SET CUTOUT:
13*
* Only visible if Gen Set /
Welder Menu selection is
not 0.

0

1

MOTION ENABLED: Motion enabled when generator is ON.

MOTION CUTOUT: Motion cutout in platform mode only.

0

H & T LIGHTS:
14

0

1

NO: No head and tail lights installed.

YES: Head and tail lights installed.

0

CABLE SWITCH:
15*
* Only visible under certain
model selections.
* Certain market and
model selections will alter
the default setting.

0

1

NO: No broken cable switch installed.

YES: Broken cable switch installed.

0

LOAD SYSTEM:
16*
* Only visible under certain
market selections.
* Certain market selections
will limit load system
options or alter default set-
ting.

0

1

2

3

4

NO: No load sensor installed.

WARN ONLY: Functions in creep, overload lamp lit, platform alarm beeps (5 sec ON, 2
sec OFF).

CUTOUT PLATFORM: All functions cutout, overload lamp lit, platform alarm beeps (5
sec ON, 2 sec OFF).

CUTOUT ALL: All functions cutout, flash overload light (500mS on, 500mS off), platform
alarm beeps (5 sec ON, 2 sec OFF).

SPECIAL 1: Functions in creep, overload lamp lit, disables main telescope out & main lift
up, platform alarm beeps (5 sec ON, 2 sec OFF).

0

Table 6-5. Machine Configuration Programming Information Software Version P6.1 to Present

Configuration Label/

Digit

Number

Description

Default

Number