Cylinders with dual counterbalance valves, 4 cylinder repair, Disassembly – JLG 600A_AJ Service Manual User Manual

Page 214: Cylinders with dual counterbalance valves -4, Cylinder repair -4, Disassembly -4

Advertising
background image

SECTION 5 - HYDRAULICS

5-4

– JLG Lift –

3121201

ports. If leakage occurs at a rate of 6-8 drops per
minute or more, the piston seals are defective and
must be replaced.

5. If no repairs are necessary or when repairs have

been made, replace counterbalance valve and care-
fully connect hydraulic hoses to cylinder port block.

6. If used, remove lifting device from upright or remove

prop from below main boom, activate hydraulic sys-
tem and run cylinder through one complete cycle to
check for leaks.

Cylinders With Dual Counterbalance Valves

(Articulating Jib Boom Lift, and Slave), Slave Level, Lower
Lift, Upright level, Main Telescope and Tower Telescope.

OPERATE ALL FUNCTIONS FROM GROUND CONTROL STATION
ONLY.

1. Using all applicable safety precautions, activate

hydraulic system.

IF WORKING ON THE TOWER BOOM LIFT CYLINDER, RAISE
TOWER BOOM HALFWAY, FULLY ELEVATE MAIN BOOM WITH
TELESCOPE CYLINDER FULLY RETRACTED AND ATTACH AN
OVERHEAD CRANE TO THE UPRIGHT FOR SUPPORT, LEAVING
APPROXIMATELY 1 INCH (2.54 CM) OF SLACK IN CHAIN OR
SLING FOR TEST PURPOSES. IF WORKING ON THE UPRIGHT
LEVEL, RAISE THE TOWER BOOM HALFWAY, THEN RAISE MAIN
BOOM TO HORIZONTAL AND POSITION A SUITABLE BOOM PROP
APPROXIMATELY 1 INCH (2.54 CM) BELOW MAIN BOOM. IF
WORKING ON THE PLATFORM LEVEL CYLINDER, STROKE PLAT-
FORM LEVEL CYLINDER FORWARD UNTIL PLATFORM SITS AT A
45 DEGREES ANGLE.

2. Shut down hydraulic system and allow machine to

sit for 10-15 minutes. If machine is equipped with
bang-bang or proportional control valves, turn IGNI-
TION SWITCH to ON, move control switch or lever
for applicable cylinder in each direction, then turn
IGNITION SWITCH to OFF. If machine is equipped
with hydraulic control valves, move control lever for
applicable cylinder in each direction. This is done to
relieve pressure in the hydraulic lines. Carefully
remove hydraulic hoses from appropriate cylinder
port block.

3. There will be initial weeping of hydraulic fluid, which

can be caught in a suitable container. After the initial
discharge, there should be no further leakage from
the ports. If leakage continues at a rate of 6-8 drops
per minute or more, the counterbalance valve is
defective and must be replaced.

4. To check piston seals, carefully remove the counter-

balance valve from the retract port. After initial dis-
charge, there should be no further leakage from the
ports. If leakage occurs at a rate of 6-8 drops per
minute or more, the piston seals are defective and
must be replaced.

5. If no repairs are necessary or when repairs have

been made, replace counterbalance valve and care-
fully connect hydraulic hoses to cylinder port block.

6. If used, remove lifting device from upright or remove

prop from below main boom, activate hydraulic sys-
tem and run cylinder through one complete cycle to
check for leaks.

5.4 CYLINDER REPAIR

NOTE: The following are general procedures that apply to

all of the cylinders on this machine. Procedures that
apply to a specific cylinder will be so noted.

Disassembly

DISASSEMBLY OF THE CYLINDER SHOULD BE PERFORMED ON A
CLEAN WORK SURFACE IN A DIRT FREE WORK AREA.

1. Connect a suitable auxiliary hydraulic power source

to the cylinder port block fitting.

DO NOT FULLY EXTEND CYLINDER TO THE END OF STROKE.
RETRACT CYLINDER SLIGHTLY TO AVOID TRAPPING PRESSURE.

2. Operate the hydraulic power source and extend the

cylinder. Shut down and disconnect the power
source. Adequately support the cylinder rod, if appli-
cable.

3. If applicable, remove the cartridge-type holding

valve and fittings from the cylinder port block. Dis-
card o-rings.

Advertising