20 automatic choke adjustment - ford engine, Automatic choke adjustment - ford engine -65 – JLG 601S ANSI Service Manual User Manual

Page 105

Advertising
background image

SECTION 3 - CHASSIS & TURNTABLE

3120746

– JLG Lift –

3-65

Green and either Amber light followed by a red light

or

then

Action:

1. Inspect and clean wiring connections.

2. Examine throttle linkage for any damage or bent

components and correct.

3. With linkage disconnected, check each potentiome-

ter for operation.

4. Reconnect linkage and reset each potentiometer for

correct operation.

5. If failure continues to occur, replace unit.

Only green light on and no actuator movement

Action:

1. Adjust trim potentiometers.

2. If problem continues, replace unit.

3.20 AUTOMATIC CHOKE ADJUSTMENT -

FORD ENGINE

1. At 70°F the choke plate should be open 1/32" (not

touching the choke bore).

2. If the ambient temperature is not 70°F, an additional

adjustment is required.

a. Loosen the three cover plate screws.
b. Adjust the cover to open the choke plate 1/32".

1/32"

Advertising