Table 3-10. EPM Diagnostic Trouble Codes

Diagnostic

Trouble

Code

Description

Cause for Setting DTC

111

Closed Loop Multiplier High (LPG)

This fault sets if the Closed Loop multiplier exceeds the limits of nor-
mal operation and cannot correctly modify the fuel flow within its lim-
its.

112

HO2S Open/Inactive (Bank 1)

This fault will set if HO2S 1 is cold, non-responsive, or inactive for 60
seconds or longer.

113

HO2S Open/Inactive (Bank 2)

This fault will set if HO2S 2 is cold, non-responsive, or inactive for 60
seconds or longer.

121

Closed Loop Multiplier High Bank 1 (Gasoline)

This fault sets if the Closed Loop multiplier exceeds the limits of nor-
mal operation. When the multiplier cannot correctly modify the fuel
flow within its limits, the limit is enforced.
NOTE: If this DTC is set in conjunction with DTC 132, the HO2S sen-
sors may be cross connected.

122

Closed Loop Multiplier Low Bank 1 (Gasoline)

This fault sets if the Closed Loop multiplier exceeds the limits of nor-
mal operation. When the multiplier cannot correctly modify the fuel
flow within its limits, it is limited at -35%.
NOTE: If this DTC is set in conjunction with DTC 131, the HO2S sen-
sors may be cross connected.

124

Closed Loop Multiplier Low (LPG)

This fault sets if the Closed Loop multiplier exceeds the limits of nor-
mal operation. When the multiplier cannot correctly modify the fuel
flow within its limits, it is limited at -35%. When this condition occurs,
the EPM perceives the engine to be running rich.

125

Closed Loop Multiplier High (Natural Gas)

This fault sets if the Closed Loop multiplier exceeds the limits of nor-
mal operation. When the multiplier cannot correctly modify the fuel
flow within its limits, it is limited at 35%. When this fault occurs, it is
because the EPM perceives the engine to be running lean.

126

Closed Loop Multiplier Low (Natural Gas)

This fault sets if the Closed Loop multiplier exceeds the limits of nor-
mal operation. When the multiplier cannot correctly modify the fuel
flow within its limits, it is limited at -35%. This occurs when the module
perceives the engine to be running rich.

131

Closed Loop Multiplier High Bank 2 (Gasoline)

This fault sets if the Closed Loop multiplier exceeds the limits of nor-
mal operation. When the multiplier cannot correctly modify the fuel
flow within its limits, the limit is enforced.

132

Closed Loop Multiplier Low Bank 2 (Gasoline)

This fault sets if the Closed Loop multiplier exceeds the limits of nor-
mal operation. When the multiplier cannot correctly modify the fuel
flow within its limits, it is limited at -35%.

141

Adaptive Lean Fault (High Limit- Gasoline)

This fault sets if the Adaptive multiplier exceeds the limits of normal
operation.

142

Adaptive Rich Fault (Low Limit Gasoline)

This fault sets if the Adaptive multiplier exceeds the limits of normal
operation.

143

Adaptive Learn High (LPG)

This fault will set if the adaptive multiplier exceeds the limits of normal
operation.

144

Adaptive Learn Low (LPG)

This fault will set if the adaptive multiplier exceeds the limits of normal
operation.