6 rotator - helac, Disassembly, Rotator - helac -14 – JLG 601S ANSI Service Manual User Manual

Page 142: Disassembly -14, Removing portion of end cap -14, Heating setscrew -14, Removing setscrew -14, Removing end cap -14, 6 rotator - helac disassembly

Advertising
background image

SECTION 4 - BOOM & PLATFORM

4-14

– JLG Lift –

3120746

minate, return the machine to a level surface, shut
down the machine, and contact a qualified techni-
cian before resuming operation.

4.6 ROTATOR - HELAC

Disassembly

1. Place actuator on a clean workbench.

2. Remove all hydraulic fittings.

3. Using a suitable hammer and chisel remove the por-

tion of end cap securing setscrew.

4. Using a torch, apply heat to the setscrews on the

bottom of actuator.

5. Remove the two (2) setscrew (4) from bottom of

actuator (1). Discard setscrew.

6. Place two (2) 3/8"x16NC bolts in threaded holes in

bottom of the actuator. Using a suitable bar, unscrew
the end cap (5). Remove the end cap from actuator
(1).

Figure 4-15. Removing Portion of End Cap

Figure 4-16. Heating Setscrew

Figure 4-17. Removing Setscrew

Figure 4-18. Removing End Cap