Manual adjustment, 16 spark arrester cleaning instructions, 17 dual fuel system – JLG 601S ANSI Service Manual User Manual

Page 96: Changing from gasoline to lp gas, Manual adjustment -56, Spark arrester cleaning instructions -56, Dual fuel system -56, Changing from gasoline to lp gas -56, Tilt switch adjustment -56

Advertising
background image

SECTION 3 - CHASSIS & TURNTABLE

3-56

– JLG Lift –

3120746

3.15 TILT ALARM SWITCH (MACHINES WITH

EXTERNAL TILT SENSOR)

PERFORM TILT ALARM SWITCH LEVELING PROCEDURE A MINI-
MUM OF EVERY SIX MONTHS TO ENSURE PROPER OPERATION
AND ADJUSTMENT OF SWITCH.

Manual Adjustment

1. Park the machine on a flat, level surface. Ensure

machine is level and tires are filled to rated pressure.

NOTE: Ensure switch mounting bracket is level and securely

attached.

2. Level the base of the indicator by tightening the

three flange nuts through approximately one quarter
of its spring travel. DO NOT ADJUST THE “X” NUT
DURING THE REMAINDER OF THE PROCEDURE.

3. With the electrical connections complete, using bub-

ble level on top of indicator, slowly tighten or loosen
the three flange nuts until indicator is level.

4. Individually push down on one corner at a time;

there should be enough travel to cause the switch to
trip. If the switch does not trip in all three tests, the
flange nuts have been tightened too far. Loosen the
“X” nut and repeat steps (2). through (4).

3.16 SPARK ARRESTER CLEANING

INSTRUCTIONS

1. Remove the cleanout plug in the bottom of spark

arrester (muffler).

2. Without causing deformation (or any type of dam-

age to the spark arrester) repeatedly tap on the
arrester near the cleanout plug. This may be enough
to begin drainage of the spark trap.

3. An industrial vacuum cleaner can do a complete job

at this point.

a. Or, IN A SAFE AREA, start the engine. Then

alternate between low idle and high idle for two
to three minutes.

b. Or, operate the engine as required by the appli-

cation for two to three minutes.

4. Install the cleanout plug. (See Table 2-4. Preventive

Maintenance and Inspection Schedule.

3.17 DUAL FUEL SYSTEM

IT IS POSSIBLE TO SWITCH FROM ONE FUEL SOURCE TO THE
OTHER WITHOUT ALLOWING THE ENGINE TO STOP. EXTREME
CARE MUST BE TAKEN AND THE FOLLOWING INSTRUCTIONS
MUST BE FOLLOWED.

Changing from Gasoline to LP Gas

1. Start the engine from the ground control station.

2. Open the hand valve on the LP gas supply tank by

turning counterclockwise.

BE SURE ALL GASOLINE IS EXHAUSTED BEFORE SWITCHING
TO LP GAS.

3. While the engine is operating, place the three posi-

tion LPG/Gasoline switch at the ground control sta-
tion to the center “off” position. Allow the engine to
operate without load, until the engine begins to
“stumble” from lack of gasoline.

4. As the engine begins to “stumble”, place the switch

to the LPG position, allowing the LP fuel to be sent
to the fuel regulator.

Figure 3-43. Tilt Switch Adjustment

Advertising