8 foot switch adjustment, Foot switch adjustment -19, Control card -19 – JLG 601S ANSI Service Manual User Manual

Page 147: Flow control card settings -19, Flow control card ramp time -19, Function speeds -19

Advertising
background image

SECTION 4 - BOOM & PLATFORM

3120746

– JLG Lift –

4-19

2. Rotating the adjustment potentiometer clockwise
will increase the ramp time.

4.8 FOOT SWITCH ADJUSTMENT

Adjust so that functions will operate when pedal is at cen-
ter of travel. If switch operates within last 1/4 in. (6.35 mm)
of travel, top or bottom, it should be adjusted.

Table 4-1. Flow Control Card Settings

Function

Minimum Current

Maximum Current

Lift Up

450 to 55o mA

1400 to 1500 mA

Lift Down

450 to 550 mA

1400 to 1500 mA

Swing Right

450 to 550 mA

1400 to 1500 mA

Swing Left

450 to 550 mA

1400 to 1500 mA

Flow Control

750 to 850 mA

450 to 550 mA

Drive Forward

40 to 60 mA

150 to 200 mA

Drive Reverse

40 to 60 mA

150 to 200 mA

Figure 4-23. Control Card

Table 4-2. Flow Control Card Ramp Time

Function

Ramp Time

Lift Up

Ramp Up Time = 4:00 sec.
Ramp Down Time = 3:00 sec.

Lift Down

Ramp Up Time = 4:00 sec.
Ramp Down Time = 3:00 sec.

Swing Right

Ramp Up Time = 4:00 sec.
Ramp Down Time = 3:00 sec.

Swing Left

Ramp Up Time = 4:00 sec.
Ramp Down Time = 3:00 sec.

Drive Forward

Ramp Up Time = 4:30 sec.
Ramp Down Time = 2:30 sec.

Drive Reverse

Ramp Up Time = 4:30 sec.
Ramp Down Time = 2:30 sec.

Flow Control

Ramp Up Time = 3:00 sec.
Ramp Down Time = 0:00 sec.

Table 4-3. Function Speeds

Function

Function Speed

In Seconds

Telescope

Extend

48-61

Retract

24-32

Lift

Up

46-60

Down

33-43

Swing Speed

Full 360

79-101

Platform Rotation

Left

22-30

Right

22-30

Drive Speed

32-36 @ 200ft.

Advertising