SECTION 3 - CHASSIS & TURNTABLE

3121813

– JLG Lift –

3-71

conductors of the harness.

5. Cut wire 106 going to the Engine/Generator Control-

ler after the existing connection point and install the
conductors that lead to the new inline fuse holder.
Use insulated butt splice connectors for these con-
ductors.

6. Re-install the harness with the new fuse in place.

7. Reconnect the lift and APU start battery. The APU is

now ready for use.