SECTION 6 - JLG CONTROL SYSTEM

6-26

– JLG Lift –

3121813

FSW1 …

Displays footswitch status
NOTE: FSW1 is wired to the power module

FSW2 …

Displays footswitch status
NOTE: FSW2 is wired to the platform module

DRIVE CUTOUT …

Displays drive cutout switch status

ELEV. CUTOUT …

Displays elevation cutout switch status

FUNC. CUTOUT …

Displays function cutout switch status

BRAKES …

Displays brake pressure switch status

MAN.RELEASE …

Displays manual brake release switch status

TILT …

Displays measured vehicle tilt
The first value indicates tilt in the forward/ reverse direction (pitch)
The second value indicates tilt in the left/ right direction (roll)

DATALOG

MAX.TEMP …

Displays maximum measured heatsink temp.

MIN.TEMP …

Displays minimum measured heatsink temp.

MAX.BATTERY …

Displays maximum measured battery voltage

ON …

Displays total controller on (EMS) time

DRIVE …

Displays total controller drive operation time

PUMP …

Displays total controller pump running time
NOTE: includes all boom functions, steer and brake release

LIFT …

Displays total controller lift operation time

SWING …

Displays total controller swing operation time

TELE …

Displays total controller tele operation time

RENTAL …

Displays total controller operation time
NOTE: can be reset

ERASE RENTAL

Not available at password level 2

YES:ENTER, NO:ESC

ENTER resets rental datalog time to zero

VERSIONS

POWER …

Displays power module software version

PLATFORM

Displays platform module software version

GROUND

Displays ground module software version

POSITILT

Displays positrac/tilt module software version

ANALYSER …

Displays Analyzer software version