Calibration descriptions -27 – JLG M600 Service Manual User Manual

Page 193

Advertising
background image

SECTION 6 - JLG CONTROL SYSTEM

3121813

– JLG Lift –

6-27

Table 6-8. Calibration Descriptions

CALIBRATIONS

Not available at password level 2; can be viewed but not changed at level 1

CONTROLLER CALS

TEMPERATURE …

Displays/adjusts heatsink temperature calibration
The setting should not be altered from that set during manufacture

TRACTION I …

Displays/adjusts traction motor current calibration
The setting should not be altered from that set during manufacture

PUMP I …

Displays/adjusts pump motor current calibration
The setting should not be altered from that set during manufacture

TILTdelayIN …

Displays/adjusts how long the tilt sensor must indicate a tilted condition before it is registered
The setting should be adjusted to optimize controller response to a sudden tilt, while minimizing spurious tilt indica-
tions during acceleration & deceleration

TILTdelayOUT …

Displays/adjusts how long the tilt sensor must indicate a not-tilted condition before it is registered
The setting should be adjusted to optimize controller response to a sudden tilt, while minimizing spurious tilt indica-
tions during acceleration & deceleration

MACHINE CALS

BRAKE

Displays/adjusts brake release speed
The setting should be adjusted to release the brakes in the desired time, with minimal effect on other boom functions

PUMP@0%

Displays/adjusts minimum pump%on
The setting should be adjusted to minimize speed variations when functions are used individually and in combina-
tions

PUMP@100%

Displays/adjusts maximum pump%on
The setting should be adjusted to minimize speed variations when functions are used individually and in combina-
tions

Vflow@0%

Displays/adjusts minimum flow control proportional valve%on

Vflow@100%

Displays/adjusts maximum flow control proportional valve%on

Vlift@0%

Displays/adjusts minimum lift proportional valve%on

Vlift@100%

Displays/adjusts maximum lift proportional valve%on

Vswing@0%

Displays/adjusts minimum swing proportional valve%on

Vswing@100%

Displays/adjusts maximum swing proportional valve%on

SPEEDprop1 …

Displays/adjusts speed control PID algorithm proportional term in traction mode
The setting should be adjusted to optimize speed control

SPEEDprop2 …

Displays/adjusts speed control PID algorithm proportional term in plugging mode
The setting should be adjusted to optimize speed control

SPEEDint …

Displays/adjusts speed control PID algorithm integral term in traction & plugging mode
The setting should be adjusted to optimize speed control

PLUGmax …

Displays/adjusts maximum plugging current
The setting should be adjusted to ensure that the vehicle can be safely stopped when being driven down maximum