SECTION 6 - JLG CONTROL SYSTEM

6-28

– JLG Lift –

3121813

Table 6-9. Calibration Ranges/Defaults

Calibration

Range

Defaults

E600

M600

BRAKE

0 to 100

25

PUMP@0%

0 to 50

6

PUMP@100%

50 to 100

100

FLOW VALVE@0%

0 to 50

44

FLOW VALVE@100%

50 to 100

60

LIFT VALVE@0%

0 to 100

40

LIFT VALVE@100%

0 to 100

70

SWING VALVE@0%

0 to 100

45

SWING VALVE@100%

0 to 100

52

TEMPERATURE

0 to 100

50

TRACTION I

0.50 to 2.00

1.00

PUMP I

0.50 to 2.00

1.00

SPEEDprop1

0 to 30

8

SPEEDprop2

0 to 30

16

SPEEDint

0.0 to 2.5

0.3

PLUGmax

30 to 100

75

TILTdelayIN*

0.0 to 5.0

1.0

TILTdelayOUT*

0.0 to 5.0

0.1

*NOTE: TiltdelayIN and TILTdelayOUT are adjusted in internal units, not in 0.1s increments.