SECTION 6 - JLG CONTROL SYSTEM

3121813

– JLG Lift –

6-33

TEST ALL INPUTS?

Prompts whether to check every operator input. If ESC is pressed, the system test ends.

If ENTER is pressed, each operator input is prompted for in turn.
In platform mode every platform switch and joystick is tested.
In ground mode every ground switch is tested.
NOTE: the jib switches are not tested if JIB = NO.

NOTE: left/right jib switches are not tested unless JIB = SIDESWING.

Prompts displayed during the operator input test include:
CLOSE switchname
The named switch should be closed.
OPEN switchname
The named switch should be opened.
joystickname direction TO MAX
The named joystick should be pushed to its full extent in the named direction.
joystickname direction TO MIN
The named joystick should be returned to neutral from the named direction.
PUMP POT TO MAX
The pump pot should be turned to maximum.
PUMP POT TO MIN
The pump pot should be turned to minimum.
MULTIPLE CLOSURE
More than one operator input is closed; if only one has been operated, there could be a short between two inputs.

TESTS COMPLETE

Indicates that the system test is complete. Any problems reported should have been noted and should now be rectified.
Press ESC to return to the RUN SYSTEM TEST Analyzer menu.

Table 6-11. System Test Messages