Table of Parameters

3.2

37

SMS text

Function No.: -

The SMS text to be sent to the preset telephone number. If the SMS text is blank,

an empty SMS is sent.

Setting options:

0-40 characters

Default setting:

blank

Send if activated longer than [ms]

Function No.: -

Set the SMS activation time necessary for SMS sending. This parameter prevents

SMS sending in the event of short-time activation. If a "0" is selected, SMS is sent

immediately upon the input activation.

Setting options:

0-25500 ms

Setting step:

100 ms

Default setting:

0 ms

Timeout after sending [s]

Function No.: -

Set the Time of inactivity after SMS sending. During this timeout no SMS is sent

even if the SMS input gets activated. This prevents sending multiple SMS units in
the case of repeated activation of the input.

Setting options:

0-2550 s

Setting step:

10 s

Default setting:

0 s

GSM & SIM Parameters

GSM

operator

lock Function

No.:

-

Provider blocking is set by manufacturer in EasyGate. If EasyGate is blocked to a

GSM provider, no other GSM provider's SIM card can be used. If an unacceptable
SIM card is used, the GSM modules does not registered to GSM and the GSM
network LED flashes quickly on the EasyGate panel.

CLIR

-

incognito

Function

No.:

41

Sets the calling line identification restriction (CLIR) for outgoing calls from

EasyGate.

Attention, before enabling it is necessary to activate this feature

by GSM operator, otherwise outgoing calls can be rejected by GSM network.

Setting options:

-According to provider - depending on how the
function is selected in the GSM network

-Activation

- ID is not sent.

-Suppression

- ID is always sent

Default setting:

According to provider

Advertising