Mounting

– Electrical Installation

2.3

31

Caution

Make sure that the cables leading through the 2N

®

Helios IP cover bottom

groove are installed properly. For the correct installation of the cables
refer to Figure 2.7.

Ethernet Connection

For the connections and meanings of the wires see the table below. Join UTP cable
wires 4 (blue) and 5 (white-blue) and attach them under terminal 7 on 2N

®

Helios IP.

In the same way, join wires 7 and 8 and place them under terminal 5 of 2N

®

Helios IP.

RJ-45

2N

®

Helios IP

Pin No. Marking Colour Terminal No.

1

Tx+

10

2

Tx –

9

3

Rx+

8

4

PoE –

6

5

PoE –

6

6

Rx –

7

7

PoE +

5

8

PoE +

5

Table 2.1 Terminal Block Connections

Electric Lock Connection

The electric lock can be connected to terminals 3 and 4 of terminal block X2.

Electric lock

2N

®

Helios IP

Marking Colour Terminal No

932070E

932080E

932090E

3

+

4

Table 2.2 Terminal Block Connection for Electric Lock

Terminals 3 and 4 are connected to a relay on the 2N

®

Helios IP board. The relay

terminals may act as normally open or normally closed contacts. Configuration is
performed through the configuration connector X1 as described in the