5. Ethernet Module Parameter Setting by PBX Configuring Tool


The 2N

®

OMEGA Lite PBX has to be equipped with the firmware version

4.02REV11 or later for the Ethernet module to work properly. If not, upgrade your
PBX.

5.1. 2N

®

OMEGA PBX Firmware Upgrade

The proper firmware upgrading procedure is as follows:

1. Read and save the PBX settings by the original PBX configuration tool.
2. Read all accounting data (if they are to be further processed).
3. Terminate all open connections.
4. Use the original configuration tool to import the firmware in the Data

– Saving

software in the PBX menu and reset and boot from flash (you will be prompted
automatically by the configuration tool).

5. Reset the factory values.
6. Launch the current configuration tool and create a new configuration (while

upgrading versions lower than 4.02), or download the originally stored
configuration).

7. Check all the PBX settings.
8. Back-up the configuration on the hard disk.
9. Export the data to the PBX.

5.2. Hardware Configuration

Having performed the PBX firmware upgrade, insert and connect the VoIP

module (with the PBX switched off). After the PBX power up download the data and
adjust all the module and PBX settings.

After downloading, the presence of the Ethernet module is indicated in the

Global data / Information in the configuration tool and in the Global data/Hardware
module.