3 installation, Installation option, 1 installation option – ADS-TEC OPC8013/8015/8022 User Manual

Page 13: Attention

Advertising
background image

OPC8013/OPC8015/OPC8022

12

© ads-tec GmbH • Raiffeisenstr.14 • 70771 Leinfelden-Echterdingen

3 Installation

3.1 Installation option

This device is designed for integration. For installation and operation reasons (connector access), the
installation location must be accessible from the rear. The wall thickness of the installation location must
be between 2 and 13 mm. We recommend at least 3 mm for proper installation with IP65 on the front.
Installation can be performed with a 2mm Allen key.

ATTENTION

To avoid overheating in operation: The device
must not be exposed to direct radiation by
sunlight or any other light source.

If the device is installed in a panel, casing or
similar, it must be ensured that no heat
accumulation occurs. The maximum permissible
ambient temperature must not be exceeded.

Devices with data drives must only be installed
vertically. Any deviation must be arranged with
ads-tec GmbH.

IP 65 on the front is only achieved with proper
installation.

ATTENTION

When selecting the enclosure for integration, the
total power dissipation of the system including
installed PCBs must be taken into account. The
housing must be dimensioned so that the max.
permissible ambient temperature is not
exceeded.

Advertising