4 commissioning, 1 available interfaces, Attention – ADS-TEC OPC8013/8015/8022 User Manual

Page 23

Advertising
background image

OPC8013/OPC8015/OPC8022

22

© ads-tec GmbH • Raiffeisenstr.14 • 70771 Leinfelden-Echterdingen

4 Commissioning

The interfaces for the device are located under protective covers. It has to be removed in order to
connect the power supply lead and the interface cables.

All supply leads and all required data leads have to be connected before commissioning.

ATTENTION

The device must be switched off before
connecting or disconnecting any cables in order
to prevent damage to the electronics!

The device may only be switched on after
acclimatising to the ambient temperature in order
to avoid condensate accumulation. Make sure to
meet the permissible voltage for this device.

After switching off and before switching on you
must wait for at least 5 seconds.

Information:

The shielding of a data cable must always be connected with the connector housing
(EMC).

For embedded operating systems, the interfaces must be explicitly enabled
and the necessary drivers installed in order to use them.

4.1 Available interfaces

Fig.

6:

Advertising