APG FLR Series user manual User Manual

Page 12

Advertising
background image

FLR Series

Rev. A5, 10/09

12

Automation Products Group, Inc.

APG...Providing tailored solutions for measurement applications

Tel: 1/888/525-7300 • Fax: 1/435/753-7490 • www.apgsensors.com • [email protected]

7. If you look closely at the reed switch assembly rod, you will notice a black
mark at each reed switch location. During factory calibration, these marks are
used to align the center of each reed switch with the desired actuation point.
To align the reed switch with the newly adjusted float position, simply move
the reed switch along the rod the same distance that you previously moved the
float stops on the stem. This distance is measured from the center of the reed
switch to the black mark on the rod.

8. Once the reed switches have been moved into the correct position, use
electrical tape to re-secure the wires to the assembly rod. You are now ready to
carefully reassemble the FLR and test the new actuation point.

6. Carefully lay the reed switch assembly on a clean surface and remove the
tape securing the wires to the assembly rod. Do not cut into the wires!

Advertising