Procedure two, Field adjustment of actuation point(s) – APG FLR Series user manual User Manual

Page 13

Advertising
background image

Rev. A5, 10/09

FLR Series

13

Automation Products Group, Inc.

APG...Providing tailored solutions for measurement applications

Tel: 1/888/525-7300 • Fax: 1/435/753-7490 • www.apgsensors.com • [email protected]

Procedure Two:

1. Determine the desired actuation point.

2. Loosen the retaining screws on float stops that need to be repositioned.

3. Slide the float along the stem until the float’s center is aligned with the
desired actuation point.

4. Re-secure the float stops 9 mm above and below the new float position (refer
to drawing below).

NOTE: The 9 mm distance between the float and stops is critical for the switch
to operate reliably.

Desired

Actuation

Point

9 mm

9 mm

• Field Adjustment Of Actuation Point(s)