8a. For “normally open” (NO) switching (code A & B switches), subtract 6 mm
from the measurement taken in step 7 and record the result. This distance will
be used to adjust the reed switch along the internal brass rod. The 6 mm is
subtracted to compensate for the plug in the bottom of the stem. Refer to
drawings below.

Actuation

Point

Indention designates

top of float

ON

OFF

For normally open (NO) switching action

with a Code "A" or "B" switch, the center

point of reed switch assembly is set in line

with the float center.

9 mm

9 mm

Normally Open Switching for Code “A” & “B” Switches