• Inspection and Maintenance

Periodic inspection is necessary to keep your FLR unit in good working
order.

CAUTION! Do not remove the housing cover until the power
supplied to the unit is turned off.

1. Keep the sensor clean.

Never leave the housing cover off. If the cover becomes

damaged or is misplaced, order a replacement immediately.

If sediment or other foreign matter is trapped between the stem

and the float, detection errors may be caused. Keep the float and

stem clean.

2. Inspect the switches and terminals.

• Technical Notes

1. The float travel stop settings are based on how the magnetic field
influences the reed switch. Normally it is not necessary to move the
stop. If the stops are moved, check the switch action for float overrun.
2. Normally Open (NO) (switch closes as level rises) and Normally Closed
(NC) (switch closes as level falls).