8b. For “normally closed” (NC) switching (code A & B switches), subtract 18
mm from the measurement taken in step 7 and record the result. This distance
will be used to adjust the reed switch along the internal brass rod. The 18 mm
is subtracted to compensate for both the offset of the reed switch from the
actuation point (-12 mm), and the plug in the bottom of the stem (-6 mm).
Refer to drawings below.

Normally Closed Switching for Code “A” & “B” Switches

For normally closed (NC) switching

action with a Code "A" or "B" switch,

the center point of reed switch assembly

is set 12mm below the actuation point.

Indention designates

top of float

ON

OFF

12 mm

Actuation

Point

9 mm

9 mm

Plug

Approx. 6 mm

Brass Rod