- Operation Method ⑥ - 

■General Settings

1.Use ▼▲ to select SET then press
when SET flashes.

2.While SET flashes, a bar graph will display
  brightness level.
Use ▼▲ to select brightness level then press
to set.

3.Use ▼▲ to select BEEP“ON”or“OFF”
then press to set.

4.Use ▼▲ to select“hkPa”or“PSI”,
then press to set.

5.Use ▼▲ to select“GT”ONLY when using SBC R (15039)
  with an external wastegate.
  
  Select "AC" when using acuator type.
Select "AC" when using SBC S (15040) regardless if actuator
or wastegate.
Press to set.

6. --- will be displayed to test connection of
Optional Wirelss Remote Switch.
Press the button on the Wireless Remote Switch.
"ON" will display if switch is properly connected.

7. Press to exit and save the general settings.
SET should no longer be illuminated, and boost level
will be displayed.

■Tuning SBC Off

1.Use ▼▲ to select“OFF”then press while
“OFF” flashes.
OFF will be illuminated, then the SBC will turn off.

Tuning SBC On
1. Hold button for 2 seconds, then "OFF" will be displayed.
2. Within 5 seconds, use ▼▲ to select LO or HI mode then press
to set.

   