■Piping to Valve Unit

●Solenoid Valve(TYPE S)
  Install the nipple follows by top plate.
  Actuator and Waste gate has a different installation method.
  Remove all the caps.

Fuel
Pressur
Regulator

Fuel Tube

Cut the hose

Intake Manifold

T pipe Joint

Nylon hose into the vehicle

■Piping to Intake Manifold

Washer

Rubber Washer

Washer

Rubber Washer

※Due to the characteristics of solenoid valve, vibration and noise will come out, but this is not defective.
 Install firmly and use φ6 crecent clamp to tie the hose.

●Dual Solenoid Valve(TYPE R)
  Install carefully IN/OUT port by looking body stamp.
  Using dual solenoid valve controlled by waste gate only, change the setting to GT.
  (Detailed information is written on page 15)

IN

OUT

Actuator Type

Wastgate Type

Using by 1/8 taper thread cannot inseat very far.

Using by 1/8 taper thread cannot inseat very far.

- Installation Method ② - 

※Due to the characteristics of solenoid valve, vibration and noise will come out, but this is not defective.
 Install firmly and use φ6 crescent clamp to tie the hose.

Please secured by wire tie