Despatch Protocol Manager with Protocol Plus User Manual

Page 51

Advertising
background image

Protocol Manager Software E-100

47

The junction boxes are used to provide a drop from the network cable to each Oven.
The cables marked "To Oven Controller" are each terminated with a 9-pin Male
subminiature "D" plug, for mating with the Oven Controller's serial data receptacle. Wire
the drop cable according to the following table:

Oven

Signal

Junction Box

Terminal

9-Pin Plug

Pin Number

Rcv +

5

2

Rcv -

4

7

Xmit +

1

3

Xmit -

2

4

Gnd

3

5



The daisy-chain and drop cables may use shielded pairs. Cable shields should be
connected as follows:

At the B&B adapter B to the earth ground terminal

At each junction box B to the box interior chassis

At each drop cable 9-pin plug B to the plug shell, if conductive; do not

connect to anything if a non-conductive shell is used