RTCSmp Built-In Temperature Controlled Hold-Line


16

Part # 4532288 Rev 3 (6/11/14)

4.6

Electrical Installation

IMPORTANT

 Refer to the specifications in chapter 3 Dimensions and Technical Specifications AND the rating

plate/instruction labels on the unit. Always refer to the rating plate/instruction labels on the unit to

verify the electrical data. Rating plate/label information overrides the information listed in this manual.

 Check and ensure that the supply voltage and the line current match the specifications given on the

rating plate. A stable mains supply must be provided.

CAUTION

Wrong voltage will damage the induction unit. Follow strictly
the specifications on the rating plate.

 The electrical connections must satisfy the national and local electrical codes.
 If ground fault current protective switches are used, they must be provided with selective activation and

designed for a minimum fault current of 30mA. Multiple generators with a mains connection must not be
connected to a single fault current protective switch.

 This induction unit is equipped with a power cable which can be connected with the necessary plug to

the socket. Ensure the plug is accessible for disconnecting from the power supply.

To setup the unit for operation:

1. Ensure the control knob is at the OFF-Position.

ON-Position

Any position where
“0”/Line is not pointing
straight up.

OFF-Position

“0” / Line is pointing
straight up.

2. Remove all objects from the glass-top and check that the glass-top is neither cracked nor broken.

CAUTION

Do not continue if the glass-top is cracked or broken.
Contact an authorized service agency for assistance.

3. Use the RJ-45 cables (provided) to connect the control units to the connectors located on the bottom of

the induction unit.

4. Connect the unit to the power supply.

5. Perform the Function Test. See chapter 5 Function Test.

Digital Displays

under Glass-Top

Plugs for

Control Units

Power Cord

Bottom View