Troubleshooting

RTCSmp

Built-In Temperature Controlled Hold-Line


Part # 4532288 Rev 3 (6/11/14)

25

10.3 Troubleshooting with Error Codes (for Service Technicians)

To obtain the internal data and error code for troubleshooting, you need an IR Adapter, proper connectors, and
software. The table below is a reference guide. For further information and assistance, please contact Garland
Technical Service.

Error Code

Possible cause

Action to take

E03
- . . . - . . .

Overheated heat sink

Let unit cool down
Check air filter and air flow

Air-cooling system obstructed

Verify that air inlet and outlet are not
obstructed with objects. Clean air filter

E04
- . . . . - . . . .

Overheated heating zone

Let unit cool down. Check air filter and air flow

E05
-. . . . .-. . . . .-

Error on power switch

Check potentiometer and its wiring.

E06
- . . . . . . - . . . . . .

Overheated electronic

Let unit cool down. Check air filter and air flow

Ambient temperature too high (the
cooling system is not able to keep the
unit in normal operating conditions)

Verify that no hot air is sucked in by the fan
Reduce the ambient temperature, the air inlet
temperature must be lower than 40ºC/110ºF

E10
- . . . . . . . - . . . . . . .

Communication BUS

Check all wiring.

E12
- . . . . . . . . - . . . . . . . .

Warning temperature heat sink

Reduce the adjusted temperature
Reduce the ambient temperature, the air inlet
temperature must be lower than 40ºC/110ºF
Verify that air inlet and air outlet are not
obstructed with objects
Check fan function

E30
- . . . . . . . . - . . . . . . . .

Interior temperature too high (central
unit)

Reduce the adjusted temperature
Reduce the ambient temperature, the air inlet
temperature must be lower than 40ºC/110ºF
Verify that air inlet and air outlet are not
obstructed with objects
Check fan function

E41
- . . . . . . . . - . . . . . . . .

Overheated Temperature-Sensor1

Let unit cool down. Reduce the adjusted
temperature. Check sensor 1.

E42
- . . . . . . . . - . . . . . . . .

Overheated Temperature-Sensor2

Let unit cool down. Reduce the adjusted
temperature. Check sensor 2.

E43
- . . . . . . . . - . . . . . . . .

Overheated Temperature-Sensor3

Let unit cool down. Reduce the adjusted
temperature. Check sensor 3.

E44
- . . . . . . . . - . . . . . . . .

Overheated Temperature-Sensor4

Let unit cool down. Reduce the adjusted
temperature. Check sensor 4.

E45
- . . . . . . . . - . . . . . . . .

Overheated Temperature-Sensor5

Let unit cool down. Reduce the adjusted
temperature. Check sensor 5.