If the <ZERO> button is released for more than 5 s, the
gauge returns the measurement mode.
The factory setting of the reset value is 1% F.S. above
the Low Trip Point and 1% F.S. below the High Trip
Point (hysteresis).
If after programming of the hysteresis the button <SP> is
pushed, the factory setting of the hysteresis (1%) is
reactivated.
Programming setpoint SP1
Programmable parameters:
(
→ [3], [4])
Low Trip Point
Low Trip Enable
Low Trip Point Hysteresis
High
Trip
Point
High Trip Enable
High Trip Point Hysteresis
Setpoint
Mode
Adjusting setpoint SP2
The adjustment procedure is the same as for setpoint SP1.
4.4 Error
Status
The setpoints SP1 and SP2 can be programmed to error status
via the diagnostic port or the EtherCAT interface.