8.6.8 Event counter
The recorder features two event counters
which can each be assigned to a logic input.
Any start value can be configured. When a
signal is applied to the corresponding logic
input (external contact), the counter is incre-
mented by one each time, if it is switched on
(status=ON).
Event counters are reset via programming
the start value. A text can be entered in each
event counter for designation.
Extra Code 259 is required.
Section 7.8
Display
Edit
Selection/input
with keys
Enter
Continue with
EVENT COUNTER
E
2 EVENT COUNTER
Select event counter:
1 — 2
h
,
R
E
2
2
2 CONTACT:
LOG.INPUT 3
Select logic input or
status:
OFF
LOG.INPUT 1
LOG.INPUT 2
...
LOG.INPUT 8
h
,
R
E
OFF:
h
forwards
R
backwards
otherwise:
3
3
2 EC STATE: ON
Select status:
OFF, ON
h
,
R
E
4
4
2 BEG VALUE:
0.000
Input start value of the
event counter
h
,
R
,
l
,
r
E
5
5
2 TEXT: _ _ _ _ _ _ _ _ _ _
Input text to designate
the event counter
(16 characters)
h
,
R
,
l
,
r
,
S
E
h
forwards
R