Safety instructions

Residual hazards

2

EN

11

Lenze ¯ BA 33.0006 ¯ 3.0

Motor protection

¯

Installed thermal detectors are no full protection for the machine.

–

If required, limit the maximum current, parameterise the controller such that it
will be switched off after some seconds of operation with I > I

N

, especially if

there is the danger of blocking.

–

Installed overload protection does not prevent an overload under any
conditions.

¯

Installed brakes are no fail−safe brakes.

–

The torque can be reduced due to disruptive factors that cannot be influenced,
e.g. by ingressing oil due to a defect shaft sealing ring on the A side.

¯

Fuses are no motor protection.

–

Use current−dependent motor protection switches at average operating
frequency.

–

Use installed thermal detectors at high operating frequency.

¯

Too high torques cause a fraction of the motor shaft.

–

The maximum torques according to catalogue must not be exceeded.

¯

Lateral forces from the motor shaft may occur.

–

Align shafts of motor and driving machine exactly to each other.

¯

If deviations from normal operation occur, e.g. increased temperature, noise,
vibration, determine the cause and, if necessary, contact the manufacturer. If in
doubt, switch off the motor.

Fire protection

¯

Fire hazard

–

Prevent contact with flammable substances.