4 feedback system, Feedback system, Electrical installation – Lenze MDFQA Operating Instructions User Manual

Page 31

Advertising
background image

Electrical installation

Plug connectors

Feedback system

6

EN

31

Lenze ¯ BA 33.0006 ¯ 3.0

6.3.4

Feedback system

Resolver (external view of poles)
Pin

Designation

Meaning

M23

1
2

+Ref
−Ref

Transformer windings
(reference windings)

3

+VCC ENP

Supply: electronic nameplate

1)

4
5

+COS
−COS

Stator windings cosine

6
7

+SIN
−SIN

Stator windings
Sine

8
9
10

Not assigned

11
12

+KTY
−KTY

Thermal sensor KTY

Incremental encoder / sin/cos absolute value encoder Hiperface (external view of poles)
Pin

Designation

Meaning

M23

1

B

Track B / + SIN

MT plug−in

connector−001.iso/dms

2
3

A
A

Track A inverse / − COS
Track A / + COS

4
5

+ U

B

GND

Supply +
Mass

6
7

Z
Z

Zero track inverse / − RS485
Zero track / + RS485

8

Not assigned

9

B

Track B inverse / − SIN

10

Not assigned

11
12

+KTY
−KTY

Thermal sensor KTY

Sin/cos absolute value encoder with EnDat interface (external view of poles)
Pin

Designation

Meaning

M23

1

UP sensor

Supply UP sensor

2
3

Not assigned

4

0 V sensor

0 V sensor supply

5
6

+KTY
−KTY

Thermal sensor KTY

7

+ U

B

Supply + / +VCC ENP

1)

8
9

Cycle
Cycle

Clock pulse EnDat interface
Clock pulse inverse EnDat
interface

10

GND

Mass

11

Shield

Shield for housing of encoder

12
13

B
B

Track B
Track B inverse

14

Data

Data EnDat interface

15
16

A
A

Track A
Track A inverse

17

Data

Data inverse EnDat interface

1) Only for versions with electronic nameplate ENP.
*

At times, older documents also stated plug sizes of 1.0 (M23) and 1.5 (M40).

Advertising