Electrical installation

Terminal box
Feedback system

6

EN

32

Lenze ¯ BA 33.0006 ¯ 3.0

6.4

Terminal box

Terminal box with knock out

Terminal box with screwed connections

MT−terminal box−001.iso

MT−terminal−box−002.iso

The openings in the terminal box are cast closed
and can be opened by the customer as required.

)

Note!

Open the holes on the underside of the knock out terminal box when the
cover is closed.

Cable glands and terminal studs for the power terminal box

Motor type /
motor size

Power connection

Screwed connections

Terminal

Terminal board

Cable

cross−section

[mm

2

]

Stripping length

[mm]

Tightening

torque [Nm]

Threaded

bolt

Tightening

torque [Nm]

MCA

10, 13,
14, 17

1 x M20 x 1.5 + 1 x M16 x 1.5

0.08 ... 2.5

10 ... 11

2)

−−−−−

−−−−−

19, 21

1 x M32 x 1.5 + 1 x M25 x 1.5

0.2 ... 10

10 ... 11

2)

−−−−−

−−−−−

20

2 x M20 + 2 x M 25 + 2 x M32

2.5 ... 16

18 ... 20

2)

−−−−−

−−−−−

22

1 x M40x1.5 + 1 x M50x1.5 +
1 x M20x1.5 + 1 x M16x1.5

10 ... 35

18

3,2

−−−−−

−−−−−

26

1 x M50 x 1.5 + 1 x M63 x 1.5 +
1 x M20 x 1.5 + 1 x M16 x 1.5

−−−−−

M12

15.5

MQA

20

2 x M20 + 2 x M 25 + 2 x M32

2.5 ... 16

18 ... 20

2)

−−−−−

−−−−−

22

1 x M40x1.5 + 1 x M50x1.5 +
1 x M20x1.5 + 1 x M16x1.5

10 ... 35

18

3.2

−−−−−

−−−−−

26

1 x M50 x 1.5 + 1 x M63 x 1.5 +
1 x M20 x 1.5 + 1 x M16 x 1.5

−−−−−

M12

15.5

MCS

09, 12,
14D,
14H,
14L15,
14P14,
19F15,
19J15

2 x M20 + 2 x M25 + 2 x M32

0.08 ... 2.5

1)

10 ... 11

2)

−−−−−

−−−−−

14L32,
14P32,
19F13,
19J30,
19P

0.2 ... 10

10 ... 11

2)

−−−−−

−−−−−

MDFQA

160

2 x M63 x 1.5 + 1 x M16 x 1.5

M12

15.5

MD

LKS 056,

071

1 x M20 x 1.5 + 1 x M16 x 1.5

0.08 ... 2.5

10 ... 11

2)

−−−−−

−−−−−

Tab. 1