Product description

Identification
Product key

3

EN

16

Lenze ¯ BA 33.0006 ¯ 3.0

5 Design, shaft, concentricity/vibrational severity/direct gearbox attachment

Design

A

Standard flange form A/FF with through hole, cyl. shaft without keyway

B

Standard flange form A/FF with through hole, cyl. shaft with keyway

C

Standard flange form C/FT with threaded holes, cyl. shaft without keyway

N

Standard flange form C/FT with threaded holes, cyl. shaft with keyway (standard attachment)

F

Same as version A except that flange is large

V

Same as version N except that flange is large

G

Same as version B except that flange is large

O

Without flange and without keyway

U

Same as version C except that flange is large

P

Without flange and with keyway

Shaft

11

Shaft 11x23 (MCS06)

24

Shaft 24x50 (MCS14; MCA14, 17)

14

Shaft 14x30 (MCS09; MCA 10)

28

Shaft 28x60 (MCS19; MCA19)

19

Shaft 19x40 (MCS12; MCA13)

38

Shaft 38x80 (MCA21)

Concentricity/vibrational severity/direct gearbox attachment

N or R

Concentricity/vibrational severity

Z0X

Direct gearbox attachment: Motor without pinion for mounting on open gearbox with pinion; flange for direct gearbox attachment without intermediate cover, with
tapered hollow shaft

Y0X

Direct gearbox attachment: Motor without pinion for mounting on open gearbox with pinion; flange for direct gearbox attachment with intermediate cover, with
tapered hollow shaft

6 Electrical connection, enclosure, cooling, load flywheel

Electrical connection

ST

Separate circular connectors for power/brake, encoder/thermal detector, fan

SQ

Shared rectangular connector for power, encoder...

KK

Separate terminal boxes for power/brake, encoder/thermal detector/fan

KG

Separate terminal boxes for power/brake, blower circular connectors for encoder, thermal detector

KS

Terminal box for power+brake; circular connector for encoder and thermal detector; circular connector for blower

SK

Circular connector for power+brake; circular connector for encoder+thermal detector; terminal box for fan

Enclosure

2

IP23

6

IP65 with shaft sealing ring

5

IP54 without shaft sealing ring (except for direct mounting on gearbox)

A

IP64 (A−flange, without shaft sealing ring) / IP65

B

IP54 with shaft sealing ring (A−bearing, oil−tight)

C

IP54 with shaft sealing ring, double lip (A bearing dust−tight)

D

IP65 with double−lip shaft sealing ring

Cooling

S00

Self cooling/without fan

F10

Blower 230V; AC; 1N

F1F

Blower 230V; AC; 1N; filter

F30

Blower 400V; AC; 3N

F3F

Blower 400V; AC; 3N; filter

F50

Blower 115V; AC; 1N

FWO

Blower 480V; AC; 3N

FWF

Blower 480V; AC; 3N; filter

Load flywheel

N

Without additional load flywheel

J

With additional mass inertia

7 Motor protection, electron. nameplate, color/specification, approval

Temperature protection

B

NC thermal contact

R

KTY sensor

E

KTY sensor; electronic nameplate

Electronic nameplate

0

Standard nameplate

2

Second nameplate supplied loose

1

Standard nameplate + electronic nameplate

3

Second nameplate supplied loose + electronic nameplate

Colour/specification

S

Colour: black

U

Specification − UL design and CSA design, approval

M

R

Specification − UL design, approval

O

8 Miscellaneous