5 feedback system, Feedback system, Electrical installation – Lenze MDFQA Operating Instructions User Manual

Page 35

Advertising
background image

Electrical installation

Terminal box

Feedback system

6

EN

35

Lenze ¯ BA 33.0006 ¯ 3.0

6.4.5

Feedback system

Resolver
Terminal

Designation

Meaning

B1
B2

+Ref
−Ref

Transformer windings
(reference windings)

B3

+ VCC ENP

Supply: electronic
nameplate

1)

B4
B5

+COS
−COS

Stator winding cosine

B6
B7

+SIN
−SIN

Stator winding sine

B8

Not assigned

R1
R2

+KTY
−KTY

Thermal sensor KTY

1) Only for versions with electronic nameplate ENP.

Incremental encoder / sin/cos absolute value encoder with Hiperface
Terminal

Designation

Meaning

B1
B2

+ U

B

GND

Supply +
Mass

B3
B4

A
A

Track A / + COS
Track A inverse / − COS

B5
B6

B
B

Track B / + SIN
Track B inverse / − SIN

B7
B8

Z
Z

Zero track / + RS485
Zero track inverse / − RS485

B10

Shield − housing

Shield − incremental encoder

R1
R2

+KTY
−KTY

Thermal sensor KTY

Sin/cos absolute value encoder with EnDat interface
Terminal

Designation

Meaning

B1

+ U

B

Supply + / + VCC ENP

1)

B2

GND

Mass

B3
B4

A
A

Track A
Track A inverse

B5
B6

B
B

Track B
Track B inverse

B7
B8

Data
Data

Data EnDat interface
Data inverse EnDat interface

B20
B21

Cycle
Cycle

Clock pulse EnDat interface
Clock pulse inverse EnDat interface

B22

UP sensor

UP sensor

B23

0 V sensor

0 V sensor

B24

Shield

Shield for housing of encoder

B25

Not assigned

R1
R2

+KTY
−KTY

Thermal sensor KTY

1) Only for versions with electronic nameplate ENP.

Advertising