Technical data

General data and operating conditions
Setting the switching frequency to the rated motor data

4

EN

20

Lenze ¯ BA 33.0006 ¯ 3.0

4.1.1

Setting the switching frequency to the rated motor data

The rated data are valid for operation on an inverter with a switching frequency of at
least 8 kHz. If operated at a switching frequency of f

ch

=4 kHz, the following

consequences must be observed.

Motor type

Consequences

MDFQA 160

¯

At f

ch

= 4 kHz, the motor continuously reaches only approx. 95 %

of its rated torque.

¯

Strongly increased noise emission

MQA 20, 22, 26
MCA 20, 22, 26

¯

At f

ch

= 4 kHz, the motor continuously reaches only approx. 95 %

of its rated torque.

¯

Increased noise emission

MCS
MCA 10, 13, 14, 17, 19, 21
MD

LKS

¯

All published rated data remain valid if f

ch

= 4 kHz.