4 technical data, 1 general data and operating conditions, Technical data – Lenze MDFQA Operating Instructions User Manual

Page 19: General data and operating conditions

Advertising
background image

Technical data

General data and operating conditions

4

EN

19

Lenze ¯ BA 33.0006 ¯ 3.0

4

Technical data

4.1

General data and operating conditions

General data

Conformity

CE

2006/95/EC

Low−Voltage Directive

Approvals

UL

ANSI/UL 1004−1
ANSI/UL 1004−6

Rotating Electrical Machines
Servo and Stepper Motors

CSA

CSA−C22.2 No. 100

Motors and Generators

Protection of persons and devices
Enclosure

See nameplate
Degrees of protection only apply to horizontal installation
All unused connectors must be closed with protection
covers or blanking plugs.

Temperature class

F (155 °C) IEC 60034 Exceedance of the temperature limit weakens or destroys

the insulation

Permissible voltage

According to limiting curve A of the pulse voltage from
IEC / TS 60034−25 (image 14)

EMC
Noise emission

IEC/EN 61800−3

Depending on the controller, see documentation for the
controller.

Noise immunity

Operating conditions

Ambient conditions
Climatic

Transport

IEC/EN 60721−3−2

2K3 (−20 °C ... +70 °C)

Storage

IEC/EN 60721−3−1

1K3 (−20 °C ... +60 °C)

< 3 months

1K3 (−20 °C ... +40 °C)

> 3 months

Operation

IEC/EN 60721−3−3

3K3 (−20 °C ... +40 °C)

Without brake

3K3 (−10 °C ... +40 °C)

With brake

3K3 (−15 °C ... +40 °C)

with blower

> +40 °C

with power reduction, see
catalogue

Site altitude

< 1000 m amsl − without power reduction
> 1000 m amsl < 4000m amsl with power reduction, see
catalogue

Humidity

Relative humidity

£ 85 %, without condensation

Electrical

The motor connection type depends on the controller

Length of the motor cable

See inverter instructions

Length of cable for speed feedback

Mechanical

IEC/EN60721−3−3

3M6

Advertising