Table 3: E94P09T4N Drive Parameters

Parameter Name

Value

Units

Min

Max

Drive name

Drive mode

Torque

Drive PWM frequency

16kHz

Current limit

.8

A

0.0000

9.0000

8kHz peak current limit

7.000

A

0.0000

7.0000

16kHz peak current limit

7.000

A

0.0000

.500

Analog input (current scale)

0.9000

A/volt

-1.8000

1.8000

Analog input (velocity scale)

100.0000

RPM/volt

-000.0000

000.0000

Enable Accel/Decel limits

Disable

Accel limit

1000.0000

RPM/sec

0.1000

5000000.0000

Decel limit

1000.0000

RPM/sec

0.1000

5000000.0000

Reference

External

Step input type

Master encoder

Fault reset

on disable

Motor temperature sensor

Disable

Motor ptc cut-off resistance

500

Ohm

000

3000

Second encoder

Disable

Regen duty cycle

10

%

1

100

Encoder repeat source

Drive feedback input

System to master ratio

1:1

-3767:1

3767:3767

Second to prime encoder ratio

1:1

-3767:1

3767:3767

Autoboot

Enabled

Group ID

0

0

3767

Enable switch function

Run

User units

1.0000

Revolutions/unit

0.0000

1000000.0000

Resolver track

0

0

15

Current Limit Max Overwrite

Disable

The “Resolver track” parameter is only applicable to the PositionServo 941 Resolver-based drive. The Resolver track func-
tion sets the pulse per revolution (PPR) resolution of the buffered encoder outputs when a resolver motor is used. Refer to the
PositionServo User’s Manual for more details. The Resolver track and Current Limit Max Overwrite functions are available with
PositionServo drive firmware revision 3.06 or higher.

2.4 Communication

There are 3 sub-folders under the [Communications] folder in the MotionView Node Tree. The Ethernet folder contains an action
button [IP setup] that permits the user to configure the Ethernet interface. The [RS485 and Modbus] folder contains the configu-
ration data of the Modbus interface. The [CAN] folder contains the configuration data for the CAN interface.

2.4.1 Ethernet

The Ethernet folder contains an action button [IP setup] that permits the user to configure the Ethernet interface. Click on the
[IP setup] button to view/change the Ethernet interface setup (The Ethernet interface may have been previously configured with
[Project] [Configuration setup], paragraph 1.3.). In [IP setup], the user can specify the IP address.