Cam designer professional – Lenze Cam Designer Professional User Manual

Page 28

Advertising
background image

Cam Designer Professional

Operation

Create a new project

28

3.0 EN - 08/2005

L

When selecting the Type "servo cam profiler 9300 EK" you can optionally indicate the

corresponding GDC file. The Gear factors and the Feed constant will then be automati-

cally read from this file.

If you have an online connection you can use the

button after the Drive input field

to assign a drive to the slave axis.

The selections under Absolute data model and Curves have a direct influence on the

maximum number of points. If you need more points for the table of base points, deac-

tivate the selection Absolute data model and use the relative data model or reduce the

value under Curves.

The maximum number of Curves depends on the selected type.

How to define the properties of the slave...

1. Go to the Slave dialog box to select the properties of the slave axis.
2. Click Next to proceed with the next step.

Input field Feed constant *

Path per revolution at the output end of the gearbox.

(If an angle is stated, one revolution = 360°)

The physical unit entered is automatically converted to the encoders.

• Enter, for instance, the leadscrew pitch.

• When entering increments, enter the number of increments per revolution.

Group field

Data of drive controller

The selection field Type serves to select a target system.

• Servo PLC/ECS servo system

• 9300 EK (9300 servo cam)

The input field GDC file serves to import a GDC file.

• Only if 9300 EK (9300 servo cam) has been selected.

The button ... serves to select a drive.

Assignment of a drive via bus address.

• The assignment is only necessary if profiles, cams etc. are to be changed.

• To change profiles, cams etc. online, all drives must be online.

Fields must be filled with * !

Dialog object

Description

Advertising