1 processing states, Cam designer professional – Lenze Cam Designer Professional User Manual

Page 33

Advertising
background image

L

3.0 EN - 08/2005

33

Cam Designer Professional

Operation

Editing settings on the worksheet

Slave axes
The following table lines represent the slave axes:

A double-click on the Name field of a slave axis opens the Properties dialog box for

the corresponding slave axis.

The status display  indicates the state of the corresponding slave axis and product.

6.3.1

Processing states

State

Meaning

--------

Product is not available in the axis (number of profiles lower than product number).

Global data diff.

The global product data do not comply with the Cam Manager.

Object vertical

There is an impermissible vertical movement (vertical line).

Overlapped Objects

Objects of the ideal cam overlap.

Objects without

Space

Same X value but different Y value of adjacent objects.

Curve not closed

The ideal cam is no closed profile.

No Interpolation

There is no interpolation point table.

Interpolation diff.

The table of interpolation points does not comply with the ideal cam.

LC Read Error

The LC9 and LC7 files cannot be read or are not available.

LC Checksum Error

When reading the LC9 and LC7 files a checksum error has been detected.

LC Globals diff.

The global data of LC9 and LC7 files do not comply with the product.

LC No Curve

Under this product number there is no profile yet in the LC9 and LC7 file.

LC Points diff.

The point values in the LC9 and LC7 files do not comply with the point table.

LC CamContactor

diff.

The cam data in the LC9 file do not comply with the product.

LC PosM/

Segment diff.

The data of the position marker of the LC9 file do not comply with the product.

OK

The cam data comply with the LC9 and LC7 file.