13 RG-MHMOD

Drive Control & Communication

5.2 Drive Control - Register #1

Table 8 illustrates the Data format of Register #1, Drive Control.

Table 8: Drive Control - Register #1

Bit

Command

Data Low Byte

0

UPDATE BUFFERS

1

LOCK SECURITY

2

STOP DRIVE

3

START DRIVE

4

UNUSED

5

UNUSED

6

UNUSED

7

UNUSED

Data High Byte

8

CLEAR SERIAL SELECT FLAG

9

SET SERIAL SELECT FLAG

10

UNUSED

11

UNUSED

12

UNUSED

13

UNUSED

14

UNUSED

15

UNUSED

The appropriate bit is set to 1. For example, to stop the drive bit two is set (send 0004H). To start the drive
send 0008H. Setting update buffers bit, enables to start the drive using downloaded data. Locking security
disables the serial drive control, the communications watchdog timer and prevents any further writing to
control or parameter registers.

NOTE 1 - Drive Control
• During each write to Register #1 only one bit should be set in the drive control word.
• If more than 1 bit is set, the drive responds to stop bit only.
• If stop bit is not set, but more than 1 bit is set, drive responds with exception code 04.

NOTE 2 - Drive Family

The QC and DL Series drives return 64 (40H) The

smd Series drives return 69 (45H)

The MC Series drives return 65 (41H)

The TC Series drives return 70 (46H)

The SC Series drives return 66 (42H)

The

Tmd Series drives return 71 (47H)

The MCH Series drives return 68 (44H)

The SMV Series drives return 72 (48H)