Installation procedures, Step 2 installing valley flashing – Metal Sales Image II Installation User Manual

Page 17

Advertising
background image

© Metal Sales Manufacturing Corporation / Subject to change without notice, effective 6/2011

17

All Valley flashings must be installed prior to panel installation.

1. Position Valley on roof, working from the low end to the high

end.

2. Attach Valley to substrate with #8-18 x

3

/

4

" Truss Head

Woodscrews, 4' o.c.

3. Make sure Truss Head Woodscrews are positioned as to be

covered by the Image II Panel when installed.

Note: If two or more Valley flashings are required, lap the Valley
flashing over the previously installed Valley flashing by a minimum
of 6" placing 2 beads of Tube Sealant between the flashings.

Step 2

Installing Valley Flashing

Moisture Barrier

Valley (1)

Truss Head Woodscrew,

4' o.c. (2)

Installation Procedures

(X) Numbers indicate sequence of installation.