Rakewall with Counter Detail

1. If the panel ends off module, bend flat part of the panel up a

minimum of 1", otherwise skip to the next note.

2. Apply a row of Double Bead Tape Sealant to the flat part of the

panel next to the panel rib or vertical field bent leg.

3. Install Rakewall to the and attach with #9-16 x 1" Woodscrews,

1' o.c. to the flat pan of the Image II panel.

4. Install Counter Flashing, and fasten to parapet wall with

appropriate fastener 1' o.c. Seal Counter Flashing to parapet

wall with Tube Sealant.

5. If two or more flashings are required, lap the flashing over

the previously installed flashing by a minimum of 2" placing a

bead of Tube Sealant between the flashings and securing with

Pop Rivets, 2" o.c.

Image II Panel (1)

#9-16 x 1" Woodscrew,

1' o.c. (4)

Moisture Barrier

Tube Sealant (7)

Fasteners By Others (5)

Rakewall (3)

Counter Flashing (6)

Double Bead

Tape Sealant (2)

Optional Rakewall

With 1" Z-Closure

(X) Numbers indicate sequence of installation.